4109 Vibro-Guard Vibration Valve

Housing and cover material: Precision cast aluminum black anodized
Internal parts: Aluminum and plated steel
Max. operating temp.: 93°C 200°F
Max. valve inlet pressure: 620 kPa 90 psi
Reset pressure: 207-1724 kPa 30-250 psi
Flow coefficient: Kv = 0.17 Cv = 0.2
Vibration sensing range: horizontal surface - 6G vertical surface - 5G
Switch ratings: 125/250 VAC:
125/250 VAC:
28 VDC:
28 VDC:
1/4 hp
10 amp
3 amp (inductive)
24 amp max. in rush