This model is a 2-Way valve for use primarily with AMOT Safety Control Systems
See datasheet for complete specifications.
AMOT Model 4126 detect's minor pressure surge that usually precedes a major crankcase explosion. It will detect the smallest pressure buildup caused by worn packing or by excessive blow-by caused by a piston and liner just beginning to scuff. This high sensitivity provides instant warning or shutdown before major damage occurs. Since the unit will not reset itself automatically.
AMOT Model 4126 detects the minor pressure surge that usually precedes a major crankcase explosion. It will detect the smallest pressure buildup caused by worn packing or by excessive blow-by caused by a piston and liner just beginning to scuff. This high sensitivity provides instant warning or shutdown before major damage occurs as the unit will not reset itself automatically.