4095 2-Way Vent Valve

SKU 4095

AMOT Model 4095 2-way vent valve is designed for manual or mechanical tripping applications where a manual reset is desired. The unit can be mounted in any position and requires a minimal force to activate.

Features and Benefits

  • Connecting rod bearing temperature detectors
  • Broken piston rod indication
  • Typically used with model 4102D
  • Envrionmentally sealed UL/CSA listed microswitch
  • No adjustments required
  • 1/2 NPT conduit connection or liquid tight hub

For gulf proof version, see Model 4395.

Specifications
Body material: Aluminum
Connections: 1/4 NPT
Net weight: 1/4 lbs.
Applications
  • Connecting rod bearing temperature detectors

  • Broken piston rod indication

  • Typically used with model 4102D

  • Replaces pneumatic model 4095

Operation

When a Model 4102D bearing temperature detector reaches a high enough temperature, the trip element will extend to brush the Model 4395 trip lever switch and cause a shutdown. This device is designed to physically replace the Model 4095, when converting from pneumatic to electric/electronic controls.