4075 / 4475 High Temperature Valves

SKU 4075-4475

The AMOT 4075 and 4475 high temperature valves provide precise temperature sensing and control for demanding industrial and engine applications. Designed to detect high gas or liquid temperatures up to 260°C (500°F), these valves are ideal for monitoring compressor discharge, lube oil, jacket water, and process temperatures.

The field-adjustable design allows temperature setpoints between 54°C and 260°C (130°F–500°F), offering wide flexibility for custom applications. Model 4075 features a rugged cast aluminum body, while model 4475 utilizes 316 stainless steel for superior corrosion resistance. Each includes a stainless-steel thermowell for extended sensor life and simplified calibration, making them low-maintenance solutions that integrate easily with AMOT shutdown systems.

For more temperature control solutions, visit our Thermostatic 2 Way Control Valves page to build a complete safety and regulation system.

Key Features & Benefits

  • Field adjustable temperature range: 54°C–260°C (130°F–500°F)
  • Choice of 316 Stainless Steel (4475) or Cast Aluminum (4075) construction
  • Reliable protection with minimal moving parts
  • Thermowell included for extended service life
  • Fast, repeatable thermal response with bimetallic disc sensor
  • Compatible with complete AMOT shutdown systems
  • Certified for PED and ATEX II 2G TX X compliance
  • Simple installation and low-maintenance design
  • Viton® seals for chemical and thermal durability
Specifications
4075 Valve body: Anodized aluminum
4475 Valve body: 316 stainless steel    
4075 Installation thread: 3/4" BSP(PL) 3/4" & 1" NPT  
4475 Installation thread: 3/4" BSP(PL), BSP (Tr) 3/4" & 1" NPT  
Port thread: 1/4" NPT    
Typical medium sensed: Gases    
Adjustable temp. trip range: 54 - 260°C 130 - 500°F  
Max. pressure at IN port: 8.62 bar 125 psi
Applications
  • Jacket water temperature

  • Compressor discharge temperature

  • Steam temperature

  • Lube oil temperature

  • Process temperature

Operation
The 4075/4475 is widely used for sensing high pressure natural gas compressor discharge temperature. When a valve is positioned at each compressor cylinder discharge manifold, an increase in temperature past the valves set point will cause the valve to vent off a control signal.
 
Removal is quick and easy removal with the stainless steel well which is supplied as part of the standard valve assembly. The valve assembly is held into the well by straight thread connections and a locking nut. Unscrewing the valve body/locknut and disconnecting the tubing fittings is all that is required to remove the valve from the well.
 

See datasheet for complete operation information.